IEC60076 |
| · |
ANSI C57 |
| · |
NEMA-TR1 |
| · |
CSA-C88-M90 |
| · |
BS |
| · |
AS2374 |
| · |
JEC-204 |
| · |
NEMA-TR1 |
| · |
ISO9001, ISO14000 |
| |
OHSAS18000 |
| |
|
| |
|
| 1. |
Production Capacity |
| |
1) Annual production capacity : 100,000MVA |
| |
¢º 200kV class factory up to 200kV |
| |
¢º 300kV class factory up to 300kV |
| |
¢º 400kV class factory up to 400kV |
| |
¢º 500kV class factory up to 500kV |
| |
¢º 800kV class factory up to 800kV |
| |
¢º Distribution transformer factory |
| |
2) Transformer MVA : up to 1,300MVA |
| |
3) Transformer voltage : up to 800kV |
| |
4) Total factory space : 600,000 ft2 |
| |
5) Manpower for Transformer factory |
| |
¢º 78 Design Engineers |
| |
¢º 50 Test Engineers |
| |
¢º 960 Workers |
| |
¢º 15 Development Engineers |
| |
|
| |
|
| 2. |
Production History |
| |
HHI is leading manufacturer in the world market |
| |
FY1978 161kV
FY1979 345kV
FY1985 400kV
FY1993 500kV
FY1997 765kV
FY1999 17,300MVA
FY2000 21,700MVA
FY2001 26,700MVA
FY2002 29,500MVA
FY2003 32,000MVA
FY2004 35,000MVA FY2006 60,000MVA FY2008 90,000MVA |
| |
|
| |
|
| 3. |
Production Range |
| |
1) Power transformer |
| |
2) Distribution transformer |
| |
3) Cast resin transformer (Up to 30kV, 7MVA) |
| |
4) Reactor |
| |
5) SF6 Gas Insulated Power Transformer |
| |
6) Special purpose transformer |
| |
|
| |
|
| 4. |
R&D and 3D CAD System |
| |
Design Department-Standardization & Manufacturing Design |
| |
1) Electro Mechanical Research Institute |
| |
-Electro Magnetic Analysis |
| |
-Thermal & Fluid Analysis |
| |
2) VIT -Ukraine |
| |
-Ultra High Voltage Transformer |
| |
-Gas Insulated Transformer |
| |
-Basic Design & Analysis |
| |
3) Industrial Research Institute |
| |
-Material |
| |
-Mechanical strength |
| |
4) Maritime Research Institute |
| |
-Vibration & Noise |
| |
5) Hunelec - Hungary |
| |
-Hybrid Insulated Transformer |
| |
-Light Weight Transformer |
| |
-Basic Design & Analysis |
| |
|
| |
|
| 5. |
Xformer with Natural Ester-based Fluids Characteristics of Natural Ester-based
Fluids |
| |
¢ºReduced Fire Liability |
| |
¢ºReduced Environmental Liability |
| |
¢ºInsulation Life Extension |
| |
¢ºPrevents Moisture Buildup in Insulation Paper |
| |
¢ºReduction in Voltage Stress Gassing Tendency |
| |
¢ºElimination of Sludge and Copper Coking |
| |
|
| |
|
| 6. |
Inspection and Test Program |
| |
1) Routine Test |
| |
¢ºWinding Resistance Measurement |
| |
¢ºRatio Check |
| |
¢ºPhase Relationship Check |
| |
¢ºInsulation Resistance Measurement |
| |
¢ºInsulation Power Factor Measurement |
| |
¢ºNo load loss & Current Measurement |
| |
¢ºImpedance Voltage & Load Loss Measurement |
| |
¢ºImpulse Test & Switching Impulse Test |
| |
¢ºInduced Over-Voltage Withstand Test |
| |
¢ºPartial Discharge & RIV Measurement |
| |
¢ºOil Leakage Test |
| |
¢ºOperation Test of All Devices |
| |
¢ºDissolved Gas in oil Analysis |
| |
¢ºCurrent Transformer Test |
| |
¢ºCalculation of Efficiency & Voltage Regulation |
| |
2) Type Test & Special Test |
| |
¢º Audible Sound Level Measurement |
| |
¢º Temperature Rise Test |
| |
¢º Auxiliary Cooling Losses Measurement |
| |
¢º Zero Sequence Impedance Voltage |
| |
¢º Pressure Test |