IEC76 |
| · |
ANSI C57.12.00 |
| · |
CSA-C88-M90 |
| · |
AS2374 |
| · |
ES140 |
| · |
ISO9001, ISO14000 |
| · |
OHSAS18000 |
| · |
JEC-204 |
| · |
DIN |
| · |
BS |
| · |
NEMA-TR1 |
| |
|
| |
|
| |
|
| 1. |
Production Capacity |
| |
1) Annual production capacity (³â°£ »ý»ê´É·Â) : 100,000MVA |
| |
¢º 200kV class factory up to 200kV |
| |
¢º 300kV class factory up to 300kV |
| |
¢º 400kV class factory up to 400kV |
| |
¢º 500kV class factory up to 500kV |
| |
¢º 800kV class factory up to 800kV |
| |
¢º Distribution transformer factory |
| |
2) Transformer MVA : up to 1,300MVA |
| |
3) Transformer voltage : up to 800kV |
| |
4) Total factory space : 600,000 ft2 |
| |
5) Manpower for Transformer factory |
| |
¢º 78 Design Engineers |
| |
¢º 50 Test Engineers |
| |
¢º 960 Workers |
| |
¢º 15 Development Engineers |
| |
|
| |
|
| 2. |
Production History |
| |
HHI is leading manufacturer in the world market |
| |
1978³â 161kV
1979³â 345kV
1985³â 400kV
1993³â 500kV
1997³â 765kV
1999³â 17,300MVA
2000³â 21,700MVA
2001³â 26,700MVA
2002³â 29,500MVA
2003³â 32,000MVA
2004³â 35,000MVA 2006³â 60,000MVA 2008³â 90,000MVA |
| |
|
| |
|
| 3. |
Production Range |
| |
1) Power transformer : Àü·Â¿ë º¯¾Ð±â |
| |
2) Distribution transformer : ¹èÀü¿ë º¯¾Ð±â |
| |
3) Cast resin transformer (Up to 30kV, 7MVA) : ¸ôµåº¯¾Ð±â |
| |
4) Reactor-¸®¾×ÅÍ |
| |
5) SF6 Gas Insulated Power Transformer : °¡½ºÀý¿¬ Àü·Â¿ë º¯¾Ð±â |
| |
6) Special purpose transformer : Ư¼ö º¯¾Ð±â |
| |
|
| |
|
| 4. |
R&D and 3D CAD System |
| |
Design Department-Standardization & Manufacturing Design |
| |
1) Electro Mechanical Research Institute : ±â°èÀü±â ¿¬±¸¼Ò |
| |
-Electro Magnetic Analysis : ÀüÀÚÀå ÇØ¼® |
| |
-Thermal & Fluid Analysis : ¿,À¯Ã¼Çؼ® |
| |
2) VIT -Ukraine |
| |
-Ultra High Voltage Transformer : Ãʰí¾Ð º¯¾Ð±â |
| |
-Gas Insulated Transformer : °¡½ºÀý¿¬ º¯¾Ð±â |
| |
-Basic Design & Analysis : ±âº»¼³°è ¹× ÇØ¼® |
| |
3) Industrial Research Institute : »ê¾÷¿¬±¸¼Ò |
| |
-Material : Àç·áÇØ¼® |
| |
-Mechanical strength : ±â°èÀû °µµÇؼ® |
| |
4) Maritime Research Institute : ¼±¹ÚÇØ¾ç ¿¬±¸¼Ò |
| |
-Vibration & Noise : Áøµ¿,¼ÒÀ½Çؼ® |
| |
5) Hunelec - Hungary : Çë°¡¸® |
| |
-Hybrid Insulated Transformer : ÇÕ¼ºÀý¿¬ º¯¾Ð±â |
| |
-Light Weight Transformer : °æ·®È º¯¾Ð±â |
| |
-Basic Design & Analysis : ±âº»¼³°è ¹× ÇØ¼® |
| |
|
| |
|
| 5. |
Xformer with Natural Ester-based Fluids Characteristics of Natural Ester-based
Fluids |
| |
¢ºReduced Fire Liability |
| |
¢ºReduced Environmental Liability |
| |
¢ºInsulation Life Extension |
| |
¢ºPrevents Moisture Buildup in Insulation Paper |
| |
¢ºReduction in Voltage Stress Gassing Tendency |
| |
¢ºElimination of Sludge and Copper Coking |
| |
|
| |
|
| 6. |
Inspection and Test Program |
| |
1) Routine Test |
| |
¢ºWinding Resistance Measurement : ±Ç¼±ÀúÇ× ÃøÁ¤ |
| |
¢ºRatio Check : ±Ç¼öºñ ÃøÁ¤ |
| |
¢ºPhase Relationship Check : À§»ó°¢ ÃøÁ¤ |
| |
¢ºInsulation Resistance Measurement : Àý¿¬ÀúÇ× ÃøÁ¤ |
| |
¢ºInsulation Power Factor Measurement : ¿ª·üÃøÁ¤ |
| |
¢ºNo load loss & Current Measurement : ¹«ºÎÇÏ¼Õ ¹× ¹«ºÎÇÏ Àü·ù ÃøÁ¤ |
| |
¢ºImpedance Voltage & Load Loss Measurement : ÀÓÇÇ´ø½º Àü¾Ð ¹× ºÎÇÏ¼Õ ÃøÁ¤ |
| |
¢ºImpulse Test & Switching Impulse Test : Ãæ°ÝÀü¾Ð ¹× ½ºÀ§Äª ÀÓÆÞ½º ½ÃÇè |
| |
¢ºInduced Over-Voltage Withstand Test : À¯µµ½ÃÇè |
| |
¢ºPartial Discharge & RIV Measurement : ºÎºÐ¹æÀü ½ÃÇè |
| |
¢ºOil Leakage Test : ´©À¯½ÃÇè |
| |
¢ºOperation Test of All Devices : ÁÖº¯±â±â µ¿ÀÛ½ÃÇè |
| |
¢ºDissolved Gas in oil Analysis : °¡½ººÐ¼® ½ÃÇè |
| |
¢ºCurrent Transformer Test : º¯·ù±â ½ÃÇè |
| |
¢ºCalculation of Efficiency & Voltage Regulation : È¿À² ¹× Àü¾Ðº¯µ¿·ü ½ÃÇè |
| |
2) Type Test & Special Test |
| |
¢º Audible Sound Level Measurement : ¼ÒÀ½ÃøÁ¤ |
| |
¢º Temperature Rise Test : ¿Âµµ»ó½Â ½ÃÇè |
| |
¢º Auxiliary Cooling Losses Measurement : ³Ã°¢½ÃÇè |
| |
¢º Zero Sequence Impedance Voltage : ¿µ»ó ÀÓÇÇ´ø½º ½ÃÇè |
| |
¢º Pressure Test : ¾Ð·Â½ÃÇè |